Language:CN

Email

Service

Promoting customer value as the driving force for the company's development

There are accurate industry information and technical data, and I believe you can find the content you are interested in here

technical service

Circuit Design of Electric Actuator
Release Time:2022-07-18      Clicks:118


How to design the circuit of the electric actuator? Let's take a look.


1. The actuator is mainly the driving device to control the valve. In short, it is to control the forward and reverse rotation of the valve. The first thing to consider is to select the size of the actuator motor according to the torque of the valve. The torque of the valve is generally between 1NM and 30000NM, and the motor is also about 0.25KW-15KW. The motor below 3KW can be controlled by the contactor and thyristor, and the motor above 3KW must be controlled by the contactor.


2. According to the process requirements of the customer's site, it depends on whether the door is a switch type or a regulation type. If it is a regulation type and the regulation is very frequent, silicon controlled rectifier must be used. Because the dark contact of silicon controlled rectifier can be regarded as unlimited use, and the service life of the contactor is 10000000 times.


3. The shutdown mode is the limit switch and torque switch that must be equipped for each actuator. If the limit switch is used for shutdown, the torque switch is used for protection, and if the torque switch is used for shutdown, the limit switch is used for protection.


4. The switch type electrical control mode is relatively simple, which can be said to be the simplest and can be used as a positive and negative rotation control circuit, while the adjustment type requires potentiometer or Hall element as feedback, which can be designed in combination with PLC or MCU.


5. If the bus control is profibus, it can be said that the domestic actuators have not reached this level, and the technology of foreign actuators is very mature


6 The power supply mode can be selected according to the power panel. In China, 380V or 220V is basically used.


Articles you are interested in
Previous:Detailed explanation of several positions and connections of solenoid valve
Next:In what areas are electric actuators used?

Back to list


Contact: Jason Zhang

Headquarters Tel:+86 186 0173 2223

24-hour customer service telephone: 400 058 3699

Email: jason@paladonsystems.com.cn

Website: www.paladonsystems.com.cn

Address: No. 888, Huanhu Road, Nanhui New Town, Pudong New Area, Shanghai